Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 601
Filtrar
1.
J Clin Med ; 13(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38730989

RESUMO

Visual field (VF) testing dates back to fifth century B.C. It plays a pivotal role in the diagnosis, management, and prognosis of retinal and neurological diseases. This review summarizes each of the different VF tests and perimetric methods, including the advantages and disadvantages and adherence to the desired standard diagnostic criteria. The review targets beginners and eye care professionals and includes history and evolution, qualitative and quantitative tests, and subjective and objective perimetric methods. VF testing methods have evolved in terms of technique, precision, user-friendliness, and accuracy. Consequently, some earlier perimetric techniques, often still effective, are not used or have been forgotten. Newer technologies may not always be advantageous because of higher costs, and they may not achieve the desired sensitivity and specificity. VF testing is most often used in glaucoma and neurological diseases, but new objective methods that also measure response latencies are emerging for the management of retinal diseases. Given the varied perimetric methods available, clinicians are advised to select appropriate methods to suit their needs and target disease and to decide on applying simple vs. complex tests or between using subjective and objective methods. Newer, rapid, non-contact, objective methods may provide improved patient satisfaction and allow for the testing of children and the infirm.

2.
J Clin Med ; 13(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610740

RESUMO

Background: Blue-yellow axis dyschromatopsia is well-known in Autosomal Dominant Optic Atrophy (ADOA) patients, but there were no data on the correlation between retinal structure and short-wavelength automated perimetry (SWAP) values in this pathology. Methods: In this cross-sectional case-control study, we assessed the correlation between best corrected visual acuity (BCVA), standard automated perimetry (SAP), SWAP, and optical coherence tomography (OCT) parameters of 9 ADOA patients compared with healthy controls. Correlation analysis was performed between BCVA, mean deviation, pattern standard deviation (PSD), and fovea sensitivity (FS) values and the OCT thickness of each retinal layer and the peripapillary retinal nerve fiber layer (pRNFL). Results: The following significant and strong correlations were found: between BCVA and ganglion cell layer (GCL) and the global (G) pRNFL thicknesses; between SAP FS and GCL and the G-pRNFL thicknesses; between SWAP PSD and total retina, GCL, inner plexiform layer, inner nuclear layer, inner retinal layer and the temporal pRNFL thicknesses. We found a constant shorter duration of the SITA-SWAP compared with the SITA-STANDARD strategy. Conclusions: SWAP, SAP, and BCVA values provided relevant clinical information about retinal involvement in our ADOA patients. The perimetric functional parameters that seemed to correlate better with structure involvement were FS on SAP and PSD on SWAP.

3.
J Clin Med ; 13(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38592688

RESUMO

Background: To evaluate changes in the visual field (VF) after Descemet stripping automated endothelial keratoplasty (DSAEK) in eyes with advanced glaucoma and previous trabeculectomy. Methods: Changes in VF, best-corrected visual acuity (BCVA), intraocular pressure (IOP), and number of glaucoma medications were analyzed before and after DSAEK in 19 eyes. The VFs were evaluated using the 10-2 program of the Humphrey Field Analyzer (HFA) and/or Goldmann perimetry (GP). Results: In nine eyes, the MD improved from -22.24 ± 6.5 dB to -18.36 ± 5.1 dB in HFA. In five out of nine eyes, postoperative MD improved >1 dB compared to preoperative MD. In GP testing, 10 out of 15 eyes showed an improvement, that is, greater than 20° in VF enlargement by the isopter of I-4e and/or new detection of a smaller or darker isopter. Overall, improvement in VF with the HFA and/or GP test was observed in 12/19 (63.2%) eyes after DSAEK. Postoperative BCVA improved by more than two lines in logMAR VA in 18 of 19 (94.7%) eyes. There were no significant differences between the preoperative and postoperative IOP and the number of glaucoma medications. Conclusions: DSAEK may produce subjective improvement in the visual field as well as improved visual acuity, even in advanced glaucomatous eyes.

4.
Ophthalmology ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38582154

RESUMO

PURPOSE: To describe visual field outcomes in the Primary Tube Versus Trabeculectomy (PTVT) Study. DESIGN: Cohort analysis of a prospective multicenter randomized clinical trial. SUBJECTS: A total of 155 eyes from 155 subjects randomly assigned to treatment with tube shunt surgery (n=84) or trabeculectomy with mitomycin C (n=71). METHODS: The PTVT Study was a multicenter randomized clinical trial comparing the safety and efficacy of trabeculectomy and tube shunt surgery in eyes without prior intraocular surgery. Subjects underwent standard automated perimetry (SAP) at baseline and annually for five years. SAP tests were deemed reliable if the false positive rate was ≤15%. Tests were excluded if visual acuity was ≤20/400 or loss of ≥2 Snellen lines from baseline were attributed to a non-glaucomatous etiology. Linear mixed-effects models were used to compare rates of change in SAP mean deviation (MD) between the two treatment groups. Intraocular pressure (IOP) control was assessed by percentage of visits with IOP <18 mmHg and mean IOP. OUTCOME MEASURES: Rate of change in SAP MD during follow-up. RESULTS: A total of 730 SAP tests were evaluated, with an average of 4.7 tests per eye. The average SAP MD at baseline was -12.8±8.3 dB in the tube group and -12.0±8.4 dB in the trabeculectomy group (p=0.57). The mean rate of change in SAP MD was -0.32±0.39 dB/year in the trabeculectomy group and -0.47±0.43 dB/year in the tube group (p=0.23). Eyes with mean IOP 14-17.5 mmHg had significantly faster rates of SAP MD loss compared to eyes with mean IOP <14 mmHg (-0.59±0.13 vs. -0.27±0.08 dB/year, p=0.012) and eyes with only 50-75% of visits with IOP <18 mmHg had faster rates than those with 100% of visits with IOP <18 mmHg (-0.90±0.16 vs. -0.29±0.08 dB/year, p<0.001). Multivariable analysis identified older age and worse IOP control as risk factors for faster progression in both treatment groups. CONCLUSIONS: No statistically significant difference in mean rates of visual field change was observed between trabeculectomy and tube shunt surgery in the PTVT Study. Worse IOP control was significantly associated with faster rates of SAP MD loss during follow-up. Older patients were also at risk for faster progression.

5.
Int Ophthalmol ; 44(1): 186, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643220

RESUMO

PURPOSE: This study introduces the Order of Magnitude (OM), a cost-effective, indigenous, virtual reality-based visual field analyzer designed for detecting glaucomatous visual field loss. METHODS: The OM test employs a two-step supra-thresholding algorithm utilizing stimuli of 0.43°diameter (equivalent to Goldmann size III) at low and high thresholds. A comparative analysis was conducted against the Humphrey visual field (HVF) test, considered the gold standard in clinical practice. Participants, including those with glaucoma and normal individuals, underwent comprehensive eye examinations alongside the OM and HVF tests between April and October 2019. Diagnostic sensitivity and specificity of the OM test were assessed against clinical diagnoses made by specialists. RESULTS: We studied 157 eyes (74 glaucomatous, 83 control) of 152 participants. Results demonstrated a high level of reliability for both OM and HVF tests, with no significant difference observed (P = 0.19, Chi-square test). The sensitivity and specificity of the OM test were found to be 93% (95% CI 86-100%) and 83% (95% CI 72.4-93%), respectively, while the HVF test showed sensitivity and specificity of 98% (95% CI 93.9-100%) and 83% (95% CI 73.9-92.8%), respectively. CONCLUSION: These findings suggest that the OM test is non-inferior to the reference standard HVF test in identifying glaucomatous visual field loss.


Assuntos
Glaucoma , Campos Visuais , Humanos , Reprodutibilidade dos Testes , Glaucoma/diagnóstico , Testes de Campo Visual/métodos , Transtornos da Visão/diagnóstico , Sensibilidade e Especificidade
6.
BMC Ophthalmol ; 24(1): 159, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600474

RESUMO

BACKGROUND: Multifocal pupillographic objective perimetry (mfPOP) is a novel method for assessing functional change in diseases like glaucoma. Previous research has suggested that, in contrast to the pretectally-mediated melanopsin response of intrinsically photosensitive retinal ganglion cells, mfPOP responses to transient onset stimuli involve the extrastriate cortex, and thus the main visual pathway. We therefore investigate the correlation between peripapillary retinal nerve fibre layer (pRNFL) thickness and glaucomatous visual field changes detected using mfPOP. Parallel analyses are undertaken using white on white standard automated perimetry (SAP) for comparison. METHODS: Twenty-five glaucoma patients and 24 normal subjects were tested using SAP, 3 mfPOP variants, and optical coherence tomography (OCT). Arcuate clusters of the SAP and mfPOP deviations were weighted according to their contribution to published arcuate divisions of the retinal nerve fibre layer. Structure-function correlation coefficients (r) were computed between pRNFL clock-hour sector thickness measurements, and the local visual field sensitivities from both SAP and mfPOP. RESULTS: The strongest correlation was observed in the superior-superotemporal disc sector in patients with worst eye SAP MD < -12 dB: r = 0.93 for the mfPOP LumBal test (p < 0.001). Correlations across all disc-sectors were strongest in these same patients in both SAP and mfPOP: SAP r = 0.54, mfPOP LumBal r = 0.55 (p < 0.001). In patients with SAP MD ≥ -6 dB in both eyes, SAP correlations across all sectors were higher than mfPOP; mfPOP correlations however, were higher than SAP in more advanced disease, and in normal subjects. CONCLUSIONS: For both methods the largest correlations with pRNFL thickness corresponded to the inferior nasal field of more severely damaged eyes. Head-to-head comparison of mfPOP and SAP showed similar structure-function relationships. This agrees with our recent reports that mfPOP primarily stimulates the cortical drive to the pupils.


Assuntos
Glaucoma , Testes de Campo Visual , Humanos , Testes de Campo Visual/métodos , Retina , Tomografia de Coerência Óptica/métodos , Fibras Nervosas , Relação Estrutura-Atividade
7.
J Curr Glaucoma Pract ; 18(1): 4-9, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38585168

RESUMO

Aim and background: Automated perimetry plays an important role in the diagnosis and monitoring of glaucoma patients. The purpose of this study is to prospectively determine parity between Humphrey visual field analyzer (HVFA) perimetry (the current gold standard) and the VisuALL virtual reality perimeter (VRP). Materials and methods: In this prospective fully paired diagnostic accuracy study, patients with stable, long-term HVFA visual fields (horizontal dots for ≥4 consecutive visits on progression analysis) with preperimetric, mild, moderate, or severe visual field loss were familiarized with the VRP and then tested using its proprietary software. These results were used for point-by-point comparison with a contemporaneous HVFA test. This study was approved by the Institutional Review Board (IRB) of the University of the Incarnate Word, San Antonio, Texas, United States of America (IRB approval #20-06-002). Results: The prospective study analyzed 43 eyes of 24 glaucoma patients. Spearman's correlation of mean deviation (MD) revealed a strong correlation between HVFA and VRP with rs(41) = 0.871, p < 0.001. The overall mean difference in locus-locus sensitivity between the devices was -0.4 ± 1.5 dB but varied for different visual field locations and glaucoma severity. Conclusion: The parity between the VRP and HVFA was remarkably strong for mild and moderate glaucoma. Given its portability, ease of use, space efficiency, and low cost, the VRP presents a viable alternative. Clinical significance: Automated perimetry, specifically the HVFA, has been the gold standard for visual field assessment since its introduction. The recent COVID-19 pandemic has illuminated the advantages of the VRP, allowing for safer visual assessment for both patient and clinician alike. Our study hopes to establish parity between these systems, allowing for the efficient integration of a novel head-mounted perimetry system that can safely diagnose and monitor glaucomatous progression in clinical practice. Precis: Investigation of parity between Olleyes VisuALL virtual reality perimetry (VRP) and existing standard HVFA perimetry is essential to the diagnosis and management of glaucoma. Linear correlations between the two were established from 43 glaucomatous eyes. Parity was strong for mild and moderate glaucoma, presenting VRP as a viable alternative. How to cite this article: Griffin JM, Slagle GT, Vu TA, et al. Prospective Comparison of VisuALL Virtual Reality Perimetry and Humphrey Automated Perimetry in Glaucoma. J Curr Glaucoma Pract 2024;18(1):4-9.

9.
Brain Sci ; 14(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38539623

RESUMO

A timely detection of visual hemifield deficits (VHFDs; hemianopias or quadrantanopias) is critical for both the diagnosis and treatment of stroke patients. The present study determined the sensitivity and specificity of four qualitative visual field tests, including face description, confrontation tests (finger wiggle), and kinetic boundary perimetry, to screen large and dense VHFDs in right-brain-damaged (RBD) stroke patients. Previously, the accuracy of qualitative visual field tests was examined in unselected samples of patients with heterogeneous aetiology, in which stroke patients represented a very small fraction. Building upon existing tests, we introduced some procedural ameliorations (incl. a novel procedure for kinetic boundary perimetry) and provided a scoresheet to facilitate the grading. The qualitative visual field tests' outcome of 67 consecutive RBD stroke patients was compared with the standard automated perimetry (SAP; i.e., reference standard) outcome to calculate sensitivity and specificity, as well as positive and negative predictive values (PPV and NPV), both for each individual test and their combinations. The face description test scored the lowest sensitivity and NPV, while the kinetic boundary perimetry scored the highest. No test returned false positives. Combining the monocular static finger wiggle test (by quadrants) and the kinetic boundary perimetry returned the highest sensitivity and specificity, in line with previous studies, but with higher accuracy (100% sensitivity and specificity). These findings indicate that the combination of these two tests is a valid approach with RBD stroke patients, prompting referral for a formal visual field examination, and representing a quick, easy-to-perform, and inexpensive tool for improving their care and prognosis.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38483610

RESUMO

PURPOSE: To compare diagnostic power for different severities of age-related macular degeneration (AMD) of two-dimensional macular pigment optical densities (2D-MPOD) and spatially matched objective perimetry, with standard perimetry and best-corrected visual acuity (BCVA). METHODS: The ObjectiveField Analyser (OFA) provided objective perimetry, and a Heidelberg Spectralis optical coherence tomography (OCT) measured 2D-MPOD in AMD patients, both completed twice over 0.99 ± 0.16 years. From each 2D-MPOD image, we extracted 20 regions/macula, matched to the 20 OFA stimuli/macula. For each region, we calculated 7 measures from the 2D-MPOD pixel values and correlated those with OFA sensitivities and delays. We quantified 2D-MPOD changes, the ability of 2D-MPOD and OFA to discriminate AMD stages, and the discriminatory power of Matrix perimetry and BCVA using percentage area under receiver operator characteristic plots (%AUROC). RESULTS: In 58 eyes of 29 subjects (71.6 ± 6.3 years, 22 females), we found significant correlations between 2D-MPOD and OFA sensitivities for Age-Related Eye Disease Studies (AREDS)-3 and AREDS-4 severities. Delays showed significant correlations with AREDS-2. For AREDS-4, correlations extended across all eccentricities. Regression associated with the Bland-Altman plots showed significant changes in 2D-MPOD over the study period, especially variability measures. MPOD per-region medians discriminated AREDS-1 from AREDS-3 eyes at a %AUROC of 80.0 ± 6.3%, outperforming OFA, Matrix perimetry, and BCVA. CONCLUSIONS: MPOD changes correlated with central functional changes and significant correlations extended peripherally in later-stage AMD. Good diagnostic power for earlier-stage AMD and significant change over the study suggest that 2D-MPOD and OFA may provide effective biomarkers.

11.
Clin Exp Optom ; 107(2): 122-129, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38467126

RESUMO

Detecting deterioration of visual field sensitivity measurements is important for the diagnosis and management of glaucoma. This review surveys the current methods for assessing progression that are implemented in clinical devices, which have been used in clinical trials, alongside more recent advances proposed in the literature. Advice is also offered to clinicians on what they can do to improve the collection of perimetric data to help analytical progression methods more accurately predict change. This advice includes a discussion of how frequently visual field testing should be undertaken, with a view towards future developments, such as digital healthcare outside the standard clinical setting and more personalised approaches to perimetry.


Assuntos
Glaucoma , Campos Visuais , Humanos , Testes de Campo Visual/métodos , Glaucoma/diagnóstico , Progressão da Doença , Transtornos da Visão/diagnóstico
12.
Bioengineering (Basel) ; 11(3)2024 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-38534524

RESUMO

Perimetry and optical coherence tomography (OCT) are both used to monitor glaucoma progression. However, combining these modalities can be a challenge due to differences in data types. To overcome this, we have developed an autoencoder data fusion (AEDF) model to learn compact encoding (AE-fused data) from both perimetry and OCT. The AEDF model, optimized specifically for visual field (VF) progression detection, incorporates an encoding loss to ensure the interpretation of the AE-fused data is similar to VF data while capturing key features from OCT measurements. For model training and evaluation, our study included 2504 longitudinal VF and OCT tests from 140 glaucoma patients. VF progression was determined from linear regression slopes of longitudinal mean deviations. Progression detection with AE-fused data was compared to VF-only data (standard clinical method) as well as data from a Bayesian linear regression (BLR) model. In the initial 2-year follow-up period, AE-fused data achieved a detection F1 score of 0.60 (95% CI: 0.57 to 0.62), significantly outperforming (p < 0.001) the clinical method (0.45, 95% CI: 0.43 to 0.47) and the BLR model (0.48, 95% CI: 0.45 to 0.51). The capacity of the AEDF model to generate clinically interpretable fused data that improves VF progression detection makes it a promising data integration tool in glaucoma management.

13.
Cesk Slov Oftalmol ; 80(2): 103-113, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38531683

RESUMO

PURPOSE: The aim of the study was to map the behavior of ophthalmologists regarding protective equipment during the COVID-19 pandemic (coronavirus disease 2019), both during the time of the mandatory restrictive measures and after their relaxation. Another aim was to evaluate the awareness of ophthalmologists in the Czech Republic about the possible impact of nose and mouth protective measures (masks, respirators) on the quality of eye examinations, especially on the results of standard automated perimetry (SAP) and intraocular pressure (IOP) measurement. MATERIALS AND METHODS: As part of two professional ophthalmological events in the Czech Republic, which took place in 2022, we obtained and evaluated data from the ophthalmologists in attendance using a questionnaire. We evaluated demographic parameters, frequency of use and type of nose and mouth protective equipment and their influence on the quality of ophthalmological examination as well as the awareness of ophthalmologists about their possible influence on the outcome of SAP and IOP measurements. RESULTS: We obtained data from a total of 212 respondents (148 women, 44 men, in 20 cases gender was not stated). In 91.5% of cases, ophthalmologists agreed that the use of respirators and masks makes ophthalmological examination more difficult. The most common problems were eyepiece fogging (85.8%), examination lens fogging (85.8%), and lens fogging when spectacles correction was prescribed (79.2%). The respondents most often combated these problems either by completely removing the respirator (24.1%) or at least by pulling it under the nose (39.2%). At the time when the measures were relaxed, significantly more men did not use any nose and mouth protection at all during ophthalmological examinations (15.8% of men vs. 4.2% of women; p = 0.032). An alarming finding was the fact that 35.6% of respondents did not know whatsoever whether the nurse was performing a perimetry examination on a patient with a respirator/mask or without protective equipment, i.e. they were not aware whatsoever of the possible formation of artifacts. Only 21.2% of respondents were aware of the possible difficulties of measuring IOP while wearing a respirator, while 59.9% of respondents were not aware of this risk (39.6% had never considered this problem, 20.3% of respondents were convinced that a respirator could not have an effect on the measurement of IOP). CONCLUSION: The use of nose and mouth protective equipment clearly affects the ophthalmological examination and makes it more difficult. Although ophthalmologists belong to a group at high risk for the possible transmission of infection in the performance of their profession, they often removed nose and mouth protection in an effort to eliminate fogging of eyepieces and examination lenses. The awareness of ophthalmologists regarding the possible influence on the results of SAP and IOP measurement by wearing a respirator was low in our questionnaire survey. It is therefore advisable to discuss this issue more widely and warn doctors about these risks.


Assuntos
COVID-19 , Masculino , Humanos , Feminino , COVID-19/epidemiologia , COVID-19/prevenção & controle , SARS-CoV-2 , Pandemias/prevenção & controle , República Tcheca , Inquéritos e Questionários
14.
Clin Exp Optom ; : 1-17, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38452795

RESUMO

Clinical imaging provided by optical coherence tomography (OCT) and its variant, OCT-angiography (OCT-A), has revolutionised eyecare practice. The imaging techniques allow for the identification and quantification of ocular structures, supporting the diagnosis and prognosis of eye disease. In this review, an overview of the usefulness of OCT-A imaging in the diagnosis and management of a range of ocular conditions is provided when used in isolation or in combination with other imaging modalities and measures of visual function (visual field results). OCT-A imaging has the capacity to identify and quantify ocular vasculature non-invasively, thereby assisting the clinician in the diagnosis or to determine the efficacy of intervention in ocular conditions impacting retinal vasculature. Thus, additional clinically useful information can be obtained in eye diseases involving conditions such as those impacting retinal vessel occlusion, in diabetic retinopathy, inherited retinal dystrophy, age-related macular degeneration, choroidal neovascularisation and optic nerve disorders. Through a clinical case series, various ocular conditions are reviewed, and the impact of OCT-A imaging is discussed. Although OCT-A imaging has great promise and is already used in clinical management, there is a lack of set standards to characterise altered vascular features in disease and consequently for prognostication, primarily due to a lack of large-scale clinical trials and variability in OCT-A algorithms when generating quantitative parameters.

15.
Arch. Soc. Esp. Oftalmol ; 99(3): 91-97, Mar. 2024. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-231135

RESUMO

Detectar y caracterizar los defectos del campo visual (CV) mediante perimetría Octopus en pacientes con glaucoma congénito primario (GCP) y determinar la calidad y duración del CV. Material y métodos: Se incluyeron 88 ojos de 70 pacientes diagnosticados de GCP. Las evaluaciones se realizaron con un Octopus 900 y cada ojo se evaluó con el algoritmo de perimetría orientada por tendencias (G-TOP). Se recogieron datos cuantitativos de CV: datos de calidad (respuestas falsa positiva y negativa, y duración del tiempo) y resultados de desviación media (DM) y raíz cuadrada de la varianza de pérdida (sLV). También se recogieron datos cualitativos: presencia de defectos difusos y localizados, hemicampo afectado y grado de defectos utilizando la clasificación de Aulhorn y Karmeyer. Se analizaron las correlaciones entre los resultados perimétricos y las variables clínicas. Resultados: La mediana de edad fue de 11 (8-17) años. El 65,9% (58/88) de los ojos con GCP presentaban defectos de CV. Se observaron defectos difusos en 10/58 ojos (16,94%) (DM media=23,92 [DE: 2,52]) dB) y defectos localizados en 48/58 ojos (82,75%). El defecto más frecuente fue el escotoma incipiente paracentral (n=15), el escalón nasal (n=8), el defecto arciforme añadido (n=2), el semianular (n=13) y el defecto concéntrico con isla central (n=9). El hemicampo visual afectado con mayor frecuencia fue el inferior. La duración media de la prueba fue de 2min 12s (DE: 21,6s). Los valores MD y sLV se correlacionaron con la agudeza visual mejor corregida, la relación excavación/disco y el número de cirugías de glaucoma (todas p<0,001). Conclusión: Se identificó un alto número de defectos difusos y localizados utilizando la perimetría Octopus en pacientes con GCP. El defecto más frecuente fue el escotoma paracentral, y el hemicampo inferior fue el más afectado.(AU)


Purpose: To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration. Material and methods: Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed. ResultsMedian age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD=23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n=15), nasal step (n=8), adding arcuate defect (n=2), half ring-shaped (n=13) and concentric defect with a central island (n=9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2min 12s (SD: 21.6s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P<.001). Conclusion: A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Glaucoma , Testes de Campo Visual/métodos , Cegueira , Anormalidades do Olho , Oftalmologia , Pediatria , Visão Ocular
16.
Ophthalmic Physiol Opt ; 44(3): 605-612, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38351866

RESUMO

PURPOSE: To explore the mechanisms of cone sensitivity loss in retinitis pigmentosa by combining two-colour perimetry with threshold versus intensity (tvi) testing. METHODS: Seven subjects with autosomal recessive retinitis pigmentosa and 10 normal subjects were recruited and underwent perimetric testing of one eye using 480- and 640-nm Goldman size V targets presented under scotopic conditions (no background illumination) and against a white background ranging in luminance from -1.5 to 2 log cd m-2 in 0.5 log cd m-2 steps. Data were fitted with tvi functions of the form logT = logT0 + log ((A + A0)/A0)n, where T is the threshold, T0 is the absolute threshold, A is the background intensity, A0 is the 'dark-light' constant and n is a gain constant. RESULTS: Reliable tvi functions could not be obtained within the region of the visual field corresponding to loss of the ellipsoid zone on optical coherence tomography. At fixation, changes in both T0 and A0 were observed, consistent with a d1 mechanism loss, which resulted in an upwards and rightwards shift of the tvi function. Losses at [±3°, ±3°] demonstrated changes in T0, consistent with a d3 mechanism loss, resulting in an upwards translation of the tvi curve. CONCLUSIONS: Although the absolute cone threshold was elevated at each location, shifts in the tvi function (so-called d1 mechanism loss) at fixation minimise threshold elevation in the presence of white adapting backgrounds, such as those typically employed in standard two-colour perimetry. At more peripheral testing locations, changes in threshold occurred independent of background luminance (so-called d3 mechanism loss). These findings suggest that backgrounds which selectively adapt rods while maintaining cones at, or near, absolute threshold may be preferable to conventional two-colour perimetry for assessing loss of cone sensitivity, especially at the point of fixation.


Assuntos
Células Fotorreceptoras Retinianas Cones , Retinose Pigmentar , Humanos , Adaptação à Escuridão , Retinose Pigmentar/diagnóstico , Campos Visuais , Visão Ocular , Testes de Campo Visual/métodos , Eletrorretinografia
17.
Adv Ophthalmol Pract Res ; 4(1): 39-44, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38406664

RESUMO

Objective: To investigate whether functional upper eyelid malposition is associated with unrecognized deficits in automated perimetry among glaucoma patients by examining patients undergoing eyelid surgery who had not been identified as requiring eyelid taping during glaucoma field testing. Methods: In this retrospective pre-post study, an automated database search followed by manual chart review was used to identify eligible patients from January 2012 to March 2020. Included patients had reliable visual field testing within two years before and after functional upper blepharoplasty or ptosis repair and no comorbid ocular diagnoses. As part of routine practice, glaucoma visual field technicians taped patients with pupil-obstructing eyelid malposition; taped examinations were excluded from analysis. Clinical and demographic characteristics, mean deviation, and pattern standard deviation were evaluated within a two year period before and after eyelid surgery. Results: The final analysis included 60 eyes of 38 patients. Change in visual field parameters after eyelid surgery did not reach statistical significance in crude or adjusted analyses. Among patients with ptosis, the margin reflex distance-1 was not associated with change in mean deviation after surgery (Pearson R2 â€‹= â€‹0.0061; P â€‹= â€‹0.700). Five of 17 eyes excluded from analysis due to unreliable pre-operative visual fields demonstrated substantial improvement after surgery. Conclusions: Functional upper eyelid malposition does not appear to cause spurious visual field abnormalities among glaucoma patients with reliable visual fields who were determined not to require eyelid taping at the time of their visual fields. Unreliable visual fields could be a sign of eyelid interference in this population.

18.
Cesk Slov Oftalmol ; 80(1): 42-51, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38365581

RESUMO

PURPOSE: Intracranial aneurysms and their hemorrhagic and thromboembolic complications represent a serious nosological unit that significantly endangers those afflicted. They are mostly asymptomatic until rupture occurs. In two case reports, we present our observations of young patients with impaired vision and headaches, in whom we found the presence of intracranial aneurysms. OBSERVATIONS: Presentation of two case reports of patients who came to our department with impaired vision and headaches. The patients underwent a complete eye examination at our center, including a visual field examination. Based on the results of the examination, they were referred for  an imaging examination of the brain, which revealed the presence of intracranial aneurysms. The patients were subsequently sent to the interventional neuroradiology center, where they underwent a noninvasive endovascular neuroembolization procedure with flow diverter implantation. We continued to monitor the patients after the procedure and document the examination results up to 1 year after the procedure. CONCLUSIONS AND SIGNIFICANCE: Thanks to the fast detection, diagnosis, and management of both patients, we prevented the occurrence of aneurysm rupture, thus a life-threatening complication. After endovascular procedures with flow diverter implantation, we observed a significant improvement in visual acuity as well as perimetric findings in both patients. When intracranial aneurysms are found within a week of the onset of eye symptoms and treated within three months, defects in the visual fields improved in our two patients within 6-12 months, and in one of the two patients the defects almost completely disappeared.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/terapia , Campos Visuais , Stents/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Transtornos da Visão/etiologia , Cefaleia/complicações
19.
Cureus ; 16(1): e51912, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38333490

RESUMO

Purpose The purpose of this study is to investigate the effect of two yellow filters (category 1: visible light transmission {VLT} from 80% to 43%) of Essilor (Kiros® and Lumior®) on standard automated perimetry (SAP) indices and Pelli-Robson (PR) contrast sensitivity (CS) testing in healthy individuals. Materials and methods This study is a prospective comparative study of 31 eyes of 31 healthy individuals aged 32.14 (8.13) years (14 males and 17 females). All participants underwent a series of three visual field (VF) examinations (24-2, Swedish Interactive Thresholding Algorithm {SITA} standard) with the Humphrey field analyzer (HFA II 740, Carl Zeiss Meditec, Jena, Germany) and three CS examinations with the PR chart (Precision Vision, Inc., Woodstock, IL). VF and CS examinations were carried out as follows: (a) no filter (NF), (b) with the yellow filter Kiros® (KIROS), and (c) with the yellow-orange filter Lumior® (LUMIOR). The effect of the two yellow filters on global VF indices (glaucoma hemifield test {GHT}, mean deviation {MD}, pattern standard deviation {PSD}, and visual field index {VFI}) and on CS score was evaluated and compared. Results When comparing the three pairs NF-KIROS, NF-LUMIOR, and KIROS-LUMIOR, no difference was presented on the global VF indices. However, a statistically significant difference was detected in the CS scores for all three pairs, favoring KIROS. It is important to note that while this difference was statistically significant, it did not reach clinical significance. Conclusions The use of yellow filters (category 1: VLT of 75% and 65%) does not affect the global VF indices and the CS of healthy individuals but significantly improves their CS score. Further studies are required to explore the clinical significance of these findings.

20.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1607-1618, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38183466

RESUMO

PURPOSE: Estimating glaucoma suspects' risk for visual field defects helps to avoid under- and over-treatment. In this retrospective, longitudinal cohort study with a very long follow-up, we studied whether pattern electroretinograms (PERG) amplitudes and blue-on-yellow visual evoked potential (BY-VEP) latencies can predict visual field defects. METHODS: Participants of the Erlangen Glaucoma Study were examined with PERG and BY-VEP between 9/1991 and 8/2001. Stimuli were created using an optical bench with Maxwellian view and consisted of vertical gratings (0,88 cpd) in a 32° field for both PERG and BY-VEP. Patients were treated according to clinical standards and performed standard automated perimetry (SAP) annually. Retrospectively, patients with normal SAP at baseline were selected. Primary endpoint was conversion to perimetric glaucoma. Predictive value was modeled using Kaplan-Meier analyses and a multivariate cox proportional hazards model with the continuous variables PERG amplitude, BY-VEP peak time and SAP square-root of loss variance (sLV) after stratification for Jonas classification of the optic discs. RESULTS: Of 412 patients (288: Jonas 0, 103: I, and 21: II; baseline age: 20-60 years), 65 converted to perimetric glaucoma during follow-up (0.5-23.3 years; median 5.5 years). Optic disc classification was a strong risk factor for conversion (log rank p < 0.0001), and patients with more advanced changes progressed earlier. In the multivariate analysis (log rank p = 0.005), only PERG amplitude remained an independent risk factor after stratification for optic disc morphology (p = 0.021), with a ~ 30% higher risk per µV amplitude decrease. CONCLUSIONS: PERG helps to estimate glaucoma suspects' risk for visual field defects.


Assuntos
Glaucoma , Hipertensão Ocular , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Testes de Campo Visual , Potenciais Evocados Visuais , Estudos Retrospectivos , Campos Visuais , Seguimentos , Estudos Longitudinais , Pressão Intraocular , Hipertensão Ocular/tratamento farmacológico , Glaucoma/diagnóstico , Eletrorretinografia , Transtornos da Visão/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...